Six Tips for More Successful Cell Cultures

Featured In: Bioscience Technology Magazine | e-Newsletters | Health | Cell Culture Apparatus | Cell Culture Apparatus | Cell Culture Systems

By By Ed Sullivan Tuesday, August 18, 2024

Loading...
For those who perform cell culture experiments, it pays to be meticulous. Even seemingly minor handling techniques and lab equipment features can make a difference in achieving success.

It can be challenging to maintain pure cell cultures and keep them healthy and growing properly. By their very nature, these cell cultures are extremely fragile. Any researcher who has had problems with cell culture health, longevity, or contamination knows how time-consuming, costly, and frustrating this can be.

Some researchers are almost superstitious about trying new cell culture vessels or media, or even altering their techniques. But not all cells types respond to growth conditions in the same way. What's more, products are continually being developed that increase convenience and efficiency in the research lab. The trick is to find ways to maximize experiment results while minimizing wasted time and money.

The following tips, compiled from interviews with experienced researchers and innovative equipment manufacturers, can help increase success rates without relying on luck.

Choose the right growth surface


There is no universal growth surface on which all cells grow well. For non-anchorage cells, be sure to select a vessel surface that is hydrophobic in order to minimize attachment.

Finding a surface for cells that you wish to attach can be a bit trickier. For example, if your cells grow poorly on a traditional, negatively-charged cell culture surface, a specialty surface with a positive charge, such as Cell+ from Sarstedt, Inc., may be a viable alternative to achieving necessary adhesion without laborious coatings.

"The transfection of adherent cells is good with Cell+ and it gives better results than traditional growth surfaces," notes Dorain Thompson, research associate at Ferring Research Institute, San Diego, Calif.

These cell scrapers from Sarstedt may be used in the "scraper" or "lifter" position. (Source: Sarstedt)



Lee Fuller, president, Fuller Labs, Fullerton, Calif., concurs, "Cell+ is very useful; my DHP and insect cells attach more quickly and growth performance is better."

Look for a vendor that offers flasks with color-coded surface options so that it is easy to differentiate them in the lab. Not only will color coding help to prevent mix-ups among various cell cultures, it also serves as a visual aid for quick and reliable identification of different growth surfaces.

Color coding on flasks makes it easy to quickly discern between suspension and adherent cells, for instance, according to Dr. Patrick McDonald, associate professor of Immunology at Université de Sherbrooke, Sherbrooke, Québec. "This is a nearly fool-proof system that benefits everyone."

Be sure that your vendor uses high-grade materials and products are manufactured under stringent purity conditions, free of pyrogens and cytotoxins. This is essential to achieving reliability and consistency for your experiments.

Also, make sure that vessel surfaces are as flat as possible. This can provide better adherence where needed and minimize "patchy" cell growth that could compromise results.

Filter out potential contaminants


Contaminants corrupt cell cultures and the results of experiments. If proper care is not taken, cell lines could be lost. Take the time and steps necessary to filter and purify everything that will come into contact with your cells.

For proper filtration, choose a membrane such as PES (Polyethersulfone), which is low in protein binding, low in extractables, and offers a high flow rate.

To make certain that media and any nutrients you might use are free of mycoplasma, use a filter with a 0.1 micron pore size.

According to Aaron Haubner, PhD, from Sarstedt, "At Sarstedt, we have put our new low-binding, 0.1 micron PES filters through extensive testing and found that they are incredibly effective at clearing mycoplasma from cell culture reagents. Our new 0.1 micron PES bottle-top filters are able to effectively clear mycoplasma even from densely-spiked large volumes, while providing similar flow rate and performance as the traditional 0.22 micron bottle top filters."

Cap carefully


Flasks with standard non-vented membrane caps are designed for use in closed systems (e.g. Leibovitz L15 media), providing a liquid- and gas-tight seal. Non-vented caps may be used in the vented position when gas exchange is desired and in the closed position when gas exchange is not desired.

When there is no requirement for anaerobic conditions, vented caps with a non-wettable hydrophobic membrane can be closed tightly to allow regular gas exchange while keeping potential contaminants out. Using a vented cap also eliminates the step of setting the cap to a vented position, and prevents the liquid buildup that sometimes forms around the inside of plug seal caps, partially sealing them and inhibiting gas exchange.

Look for quick-release caps for one-handed attachment or removal. Generally, cell culture flasks with traditional screw caps require one or more turns to remove or replace the cap. A quick-release cap design should require less than a full turn. "The Sarstedt flasks with quick release caps allow for a quick and easy opening with one hand under the hood,"says McDonald.

Do not disturb


Just like an infant, your cell culture does not like excessive noise or movement. Make certain that your incubator is level, stable and in a location away from heavy foot traffic or vibrating, motorized instrumentation, such as compressors, laminar flow hoods, or centrifuges. Also make sure it has a rattle-free fan and that the shelving allows for a uniform temperature profile. Bear in mind that temperature fluctuations will more likely occur in the front of the incubator, so keep your more critical experiments toward the back of the storage compartment.

"I believe that researchers experience this problem more often than you might think," says Pillari Ratnakar, PhD, veteran cell culture researcher. "I have seen instances where an incubator was placed next to a centrifuge and a staff member thought there was a problem with the culture vessel, incubator or culture medium, for example. The real problem was the agitation caused by the centrifuge equipment, and it ruined the experiment by causing cells to form different circular growth patterns on dishes."

Be flexible


Cell scrapers are useful tools that allow researchers to remove cells without using chemicals to dislodge them in preparation for experiments. However, choosing the proper scraper design is critical. For example, many cell scrapers have hard, inflexible blades that can cause more cell damage than successful removal. To avoid such unnecessary or excessive damage, consider using a cell scraper with a thin, flexible, non-toxic blade material.

More advanced cell scraper designs can also include adjustable, swiveling blades that are easier to use even in culture containers that can be difficult to access. This type of scraper blade can be aseptically turned 90° from the "scraper" position, making it ideal for use in flasks, to the "lifter" position, which is useful for harvesting cells in dishes.

Freeze cautiously


Once you have grown your cell culture, remember that freezing and thawing are critical for successful preservation and recovery. Follow an established freezing protocol and always use storage tubes that are specifically designed for cryogenic use. Also, be sure to use cryo tubes that are tested and certified to be completely free of potential contaminants that would harm cell materials and cellular components during preservation.

Freeze your cells in a container at -80°C with a cooling rate of 1°C/minute for several hours before transferring them to a liquid nitrogen tank. Store these samples in the gas phase of the tank to prevent contamination from frozen organisms in the liquid nitrogen. Taking this precaution also avoids potential tube breakage due to liquid nitrogen entry and expansion during thawing.

When thawing, use a 37° C water bath with cover. Disinfect the tube before opening with 70% alcohol.

To avoid confusion or mixing of frozen samples, consider using a tube system with color-coding. In its CryoPure system, for example, Sarstedt offers a total of 25 different color combinations for its tubes.

"The main point is, once you have successfully grown your cells and are ready to store them long term, you don't want to risk losing them during freezing," advises Ratnakar.

Attention to detail is the name of the game in preparing and storing cell cultures. Make careful decisions about techniques and equipment, continue to look for ways to increase efficiency, and you'll avoid the headache of lost cell lines and ruined experiments.
Ed Sullivan is a Hermosa Beach, Calif. based writer that has researched and written about high technologies and healthcare for more than 25 years.
Join the Discussion
Rate Article: Average 0 out of 5
register or log in to comment on this article!

0 Comments

Add Comment

Text Only 2000 character limit

Page 1 of 1

Research Exchange

Handle With Care

Aug 26

Researchers face the dual challenges of difficult to handle and hard to maintain stem cells.

Six Tips for More Successful Cell Cultures

Aug 18

For those who perform cell culture experiments, it pays to be meticulous. Even seemingly minor handling techniques and lab equipment features can make a difference in achieving success.

Rapid Generation of Assay-ready Serial Dilution Plates Using Two-stage Low Volume Pipetting

Jul 22

Researchers see the benefits of streamlining accurate serial dilution of stock solutions of compounds. By Joby Jenkins, TTP LabTech As the cost of drug development escalates there is a growing requirement to accelerate the R&D cycle and eliminate unwanted off-target drug effects earlier.

Imaging Through the Pipeline

Jun 15

The evolution of live animal imaging technology has helped researchers get a better picture of the drug research process, from target identification to pharmacokinetic studies.

The Future of the FDA: Operating in an Electronic World

Oct 12

Acording to an Axendia reseach study, the FDA is currently shifting its organizational and technology infrastructures to facilitate electronic interactions with the companies it regulates.

Tissue Microarrays - Opening up new opportunities in the Therapeutics sector

Oct 12

Tissue Microarray has become a pivotal cog in the wheel for high throughput studies and is an integral part in the validation process for screening results from discovery platforms for expression studies using various approaches.

Translational Informatics for Systems Biology

Oct 12

A study in which IO Informatics' Sentient software has been applied to integrating and linking a customer's multiple data streams.

De Novo Formula Generation with Sub-ppm Confidence

Oct 12

Novel technology embodied in the micrOTOF allows precise measurement of both accurate mass and True Isotopic Pattern (TIP) over a wide dynamic range, allowing for the implementation of an open access system.

ADP-Glo™: An Ideal Approach to Monitor the Activity of Protein Kinases and Beyond

Oct 16

Because of its versatility (alltypesofsubstrates), robustness (Z’>0.8), rapidperformance, and its ease of use, the luminescence based Kinase Glo® assay platform has gained wide acceptance in many drug screening programs for protein kinase inhibitors.

A Cell-Based, Microplate Format, DELFIA Assay for Determination of the Activation of MAP KinaseSofia

Oct 16

Mitogen-activated protein kinases(MAPK) are activated in response to extracellularsignals or cellular stress. We have set up a cell-based DELFIA®Time-Resolved Fluorescence assay to test compounds or conditions for their ability to modulate cellular stress by the activation of MAPK.

Cell Based Assays for Studying the Effects of Cytotoxic Agents

Oct 16

Apoptosis, DNA fragmentation and cell proliferation are important parameters when studying live cell function, especially, when the effects of cytotoxic agents are under study.

Evaluation of cadmium, lead, nickel and zinc status in biological samples of smokers and nonsmokers hypertensive patients

2 hours ago

The objective of this study was to evaluate the association between trace and toxic elements zinc (Zn), cadmium (Cd), nickel (Ni) and lead (Pb) in biological samples (scalp hair, blood and urine) of smoker and nonsmoker hypertensive patients (n=457), residents of Hyderabad, Pakistan. For the...

Angiotensin-converting enzyme gene and retinal arteriolar narrowing: The Funagata Study

2 hours ago

The purpose of this study is to determine whether the angiotensin-converting enzyme (ACE) gene polymorphism is associated with retinal arteriolar narrowing, a subclinical marker of chronic hypertension. The Funagata Study examined a population-based sample of Japanese aged 35+ years; 368...

EDITORIAL STATEMENT

2 hours ago

 

Request for Entries

Oct 16

Ask the Experts is your chance to get the answers to questions on applications, materials, methods, processes, and technologies. Email you question to bst_web@advantagemedia.com, and the editors of Bioscience Technology will find an appropriate expert to answer it. Watch this space in the future to see the questions your colleagues are posting.

STAY INFORMED: SUBSCRIBE TO

Magazine and E-mail Newsletters

Loading...
E-mail:   

MULTIMEDIA

Video:

Frontiers in Bioscience Learning and Memory Video

Oct 6

How does the brain learn and remember? An academic conference "Frontiers in Bioscience Learning and Memory" was held at City University of Hong Kong on June 16th.

Podcasts:

Allen Institute for Brain Research

Oct 14

Discussed in this interview are both the mouse brain project and the human cortex project with an emphasis on the importance of these projects to neuroscience research.