Minimizing Assays- Increasing Returns

Featured In: Automated Dispensers

Wednesday, September 20, 2024

Loading...
Researchers utilizing HTS screening methods have been charged with finding greater active compound hits in shorter periods of time. More often than not, costs for screening methods had increased as throughput increased. In order to manage their goals within cost boundaries, HTS researchers have turned to manufacturers of HTS-related products and equipment to help them generate more efficiencies.

Example of costs to screen 250,000 assay sample points. Click here to enlarge.
Screening assays for therapeutic compounds were at one time performed in glass vials or tubes - an arduous and expensive task, generating very little information over a long period of time. This method was revolutionized in the 1970's with the introduction of 96-well microplates specific for immunoassays. Researchers quickly modified screening assays into this new format; testing more compounds in less time, and with significantly lower raw material costs. Initial costs to validate the new assay format were quickly recouped through the overall reduction in raw materials.

Within two short decades, the screening industry pushed the limits of technology further with the introduction of higher density microplates in 384-well and 1536-well formats. In each configuration, more compounds could be screened with less raw material costs - a significant increase in "bang" using fewer "bucks". Although higher density microplates are being developed, Gary Barush, Director of Marketing and Sales at BioTek Instruments, Inc., questions whether this assay development trend will continue beyond 1536-well formats.

"Issues that are present but manageable in 96-well and 384-well microplates can develop as daunting problems in ultra-high density microplates," he noted. "Evaporation and background interference are just a few obstacles that can pose major problems in this format. At this point, assay optimization in compound screening is at a plateau until we can develop completely new modes of chemistry and technology."

NanoQuot sub-microliter microplate dispenser from BioTek Instruments, Inc.
Additionally, Barush states that any savings from moving to ultra-high density microplates is easily countered by the cost of the microplates as well as the microplate equipment used within the process. The result would be an overall increase, not a decrease, in cost.

In fact, over 95% of microplate users plan to stay in 96-well, 384-well or 1536-well formats in the coming year, and have no plans to transition into higher density microplates for HTS applications.

So if ultra-high density microplates aren't the answer, how do researchers find additional cost savings? The answer lies in the reagent volumes. Reagent costs are the most significant recurring expense for HTS compound screening assays and their development. A simple reduction in the reagent volume can add up to a significant reduction in overall expenses. A 384-well low volume microplate, designed specifically for sub-microliter assays, can provide up to a four-fold reduction in working volume when compared to a traditional 384-well microplate.

With the increasing popularity of 384-well low volume microplates, HTS researchers can benefit from reagent cost reduction while operating on the same equipment. The use of sub-microliter assays, using the same overall microplate footprint with a lower reagent volume, is forecast to grow over 60% within the next year as more laboratories search for more results at less overall cost.

Traditionally, liquid dispensers used in this process fell into two categories. Common microliter dispensers are economical for most laboratories, but suffer from decreased accuracy and precision at the lowest volume range. On the other hand, highly accurate nanoliter dispensers have been cost-prohibitive.

The NanoQuot sub-microliter microplate dispenser (BioTek Instruments, Inc., Winooski, VT) bridges the gap between these dispensing groups, combining economy and precision. The unit's eight solenoid valves rapidly deliver volumes from 0.1 to 40 μl, with dispensing accuracy and precision of less than 5% at 1 μl. Flexibility in microplate format — 96-well, 384-well, 384-well low volume, and 1536-well microplates — means that researchers can easily transition into lower volume assay configurations.

NanoQuot's eight solenoid valves provide rapid delivery for a variety of applications.
As in the historical transition from tubes to microplates, initial costs to validate the assay in a low-volume format are quickly recovered through the significant reduction in reagent expenses. Meanwhile, backward compatibility with existing formats and volumes allows for assay validation in low-volumes while still producing results in the existing format. The same reagents can be used for robust assays, and capital expenses are non-existent as the low-volume assays are processed on existing equipment. Finally, one more bonus exists for the lab manager in the form of flat or reduced labor costs associated with these more efficient assays.

About the author
Jason Greene, a Product Manager at BioTek Instruments, can be reached at Greenej@biotek.com.

Join the Discussion
Rate Article: Average 0 out of 5
register or log in to comment on this article!

0 Comments

Add Comment

Text Only 2000 character limit

Page 1 of 1

Research Exchange

Automated Forensic DNA Methods: Relieving the Pain of Validation

Apr 21

Automation can increase a forensics lab's sample processing capacity, but it can also add to the complexity of system verification and validation.

Successful Sample Identification

Apr 1

2D Barcodes ensure that a multitude of samples can be tracked in a variety of storage conditions.

Multi-Parametric Cellular Analysis

Mar 23

Flow cytometers perform a variety of multi parametric applications and have been used for an expanding set of cell analysis applications over the past forty years.

Maintaining a Healthy Cell Culture Environment

Mar 23

Investing in best practices and products at the beginning of any experiment is the most time- and cost-effective way to approach cell culture.

Step up to the MIQE

Mar 30

Over the years, polymerase chain reaction (PCR) has evolved into a readily automated, high throughput quantitative technology. Real-time quantitative PCR (qPCR) has become the industry standard for the detection and quantification of nucleic acids for multiple application, including quantification of RNA levels. But a lack of consensus among researchers on how to best perform and interpret qPCR experiments presents a major hurdle for advancement of the technology. This problem is exacerbated by insufficient experimental detail in published work, which impedes the ability of others to accurately evaluate or replicate reported results.

Fast Optimization of a Multiplex Influenza Identification Panel Using a Thermal Gradient

Mar 30

The year 2009 was marked by the emergence of a novel influenza A (H1N1) virus that infects humans. There is a need to identify the different strains of influenza virus for purposes of monitoring the H1N1 strain pandemic and for other epidemiological and scientific purposes.

Advantages of Monolithic Laser Combiner Technology in Confocal Microscopy Systems

Jan 6

Fluorescence microscopy techniques require a reliable light source at the desired wavelength or wavelengths, with minimal downtime for maintenance and alignment. Lasers are a popular light source, although the alignment and upkeep of laser combiners is a time-consuming prospect for many users.

Size-Exclusion Chromatography for Purification of Biomolecules

Dec 2 2009

Size-exclusion chromatography (SEC) is a popular method to separate biomolecules based on their size. Primarily, it is applied to the separation of biopolymers such as proteins and nucleic acids, i.e. water-soluble polymers.

Using the Tecan Genesis Workstation to Automate a Cytometric Bead Array (CBA) Immunoassay

Mar 11

The poster describe the process involved in automating a Cytometric Bead Array (CBA) immunoassay developed to measure relative concentrations of serum antibodies against Tetanus (TT), Sperm Whale Myoglobin (SWM) and Keyhole Limpet Hemocyanin (KLH) in KLH-immunized volunteers.

Ensuring Quality in Assays Performed with Automated Liquid Handlers

Feb 2

The focus of this presentation is to highlight the need of ensuring quality in important assays performed with automated liquid handlers. Nearly all assays performed within a laboratory are volume-dependent. In turn, all concentrations of biological and chemical components in these assays, as well as the associated dilution protocols, are volume-dependent. Because analyte concentration is volume-dependent, an assay’s results might be falsely interpreted if liquid handler variability and inaccuracies are unknown or if the system(s) go unchecked for a long period.

Inkjet System for Protein Crystallography

Feb 1

X-ray crystallography is used routinely by scientists to obtain the three dimensional structure of a biological molecule of interest.Such information can be used to determine how a pharmaceutical interacts with a protein target and what changes might improve functionality. However, the crystallization of macromolecules still remains a serious hindrance in structural determination despite impressive advances in screening methods and technologies.

Attention Deficit & Hyperactivity in a Drosophila Memory Mutant

Attention Deficit & Hyperactivity in a Drosophila Memory Mutant

Nov 9 2009

Action selection is modulated by external stimuli either directly or via memory retrieval. In a constantly changing environment, animals have evolved attention-like processes to effectively filter the incoming sensory stream. These attention-like processes, in turn, are modulated by memory. The neurobiological nature of how attention, action selection and memory are inter-connected is unknown. We describe here new phenotypes of the memory mutant radish in the fruit fly Drosophila.

A situation-specific theory of Midlife Women's Attitudes Toward Physical Activity (MAPA).

Apr 28

This paper presents a situation specific theory-the Midlife Women's Attitudes Toward Physical Activity (MAPA) theory-that explains how women's attitudes toward physical activity influence their participation in physical activity. Using the integrative approach of Im, the theory...

Ultrasound-guided core biopsy for investigation of cervical lymph node: chronic lymphocytic leukaemia and metastatic squamous cell carcinoma.

Apr 28

We describe a case in which ultrasound-guided fine needle core biopsy of a cervical lymph node enabled diagnosis of dual disease. Histological examination of the core biopsy confirmed unsuspected chronic lymphocytic leukaemia with an isolated focus of metastatic squamous cell...

Prokariotic Cell Collection in Denmark

Nov 6 2009

I would like to know about a prokariotic cell collection in Denmark. Is there a cell bank in this country? I need a Lactobacillus strain for a fermentation assay and this information about the bank is very helpful for me.

Request for Entries

Oct 16 2009

Ask the Experts is your chance to get the answers to questions on applications, materials, methods, processes, and technologies. Email you question to bst_web@advantagemedia.com, and the editors of Bioscience Technology will find an appropriate expert to answer it. Watch this space in the future to see the questions your colleagues are posting.

STAY INFORMED: SUBSCRIBE TO

Magazine and E-mail Newsletters

Loading...
E-mail:   

MULTIMEDIA

Video:

Neuroscience Diseases of The Brain and How The Mind Emerges

Neuroscience Diseases of The Brain and How The Mind Emerges

Nov 8 2009

Dennis Choi, director of Emory Universitys Neuroscience Center, is renowned for his groundbreaking research on brain and spinal cord injury.

Podcasts:

Allen Institute for Brain Research

Allen Institute for Brain Research

Oct 14 2009

Discussed in this interview are both the mouse brain project and the human cortex project with an emphasis on the importance of these projects to neuroscience research.

Information: