Today’s fume hoods last longer, keep researchers safer and provide more flexibility.

Few labs if any lack a fume hood or two. The hoods of the past, though, cannot keep up with modern needs. Consequently, manufacturers keep increasing the capabilities of fume hoods.

A filtered-based hood from Thermo Fisher Scientific’s Hamilton Laboratory Furniture and Fume Hoods can use powered bases to adjust to a user’s height. (Source: Thermo Fisher Scientific)

For example, The Baker Company developed the BioChemGARD e3. Dan Eagleson, vice president, marketing and business development at The Baker Company, describes it as “a class II, type B2 total exhaust biological safety cabinet that … was engineered specifically for laboratories that need containment and removal of vapors, mists and particulates and has been tested in accordance with ANSI/ASHRAE 110-1995.”

In developing this hood, says Eagleson, they focused on three crucial components: energy efficiency, productivity and comfort. “By operating at only 664 cubic feet per minute,” says Eagleson, “the BioChemGARD e3 minimizes noise, cuts electrical power requirements by 70 percent compared to traditional B2 cabinets and reduces the volume of conditioned air that is exhausted from the laboratory.” He adds, “The new StediFLOW VFD motor controller maintains precise airflow by self-adjusting for filter loading.”

This fume hood also reduces maintenance. As Eagleson explains: “Baker’s exclusive ‘sealed access exhaust filter exchange system’—located directly under the work surface for improved access—minimizes exposure to contaminants and allows for faster, simpler maintenance.” He adds, “Our system permits filter bagging and exchanges within the work surface, providing improved access, a simpler process and an overall reduction in maintenance time while still minimizing exposure to contaminants by running the exhaust during the filter change.”

Doing Away with Ducts
“About every decade, there’s been a major shift in the fume-hood industry,” says Jon Zboralski—director of airflow products at Thermo Fisher Scientific’s Hamilton Laboratory Furniture and Fume Hoods. “We’re probably at that start of one now.” According to Zboralski, “The major change is new technology to build conventionally sized fume hoods for general-purpose usage using a filter instead of ducting them.”

Filter-based hoods can save money over ducted ones. For example, a filter-based hood does not need the ductwork required for a conventional one. It also recirculates air back to the lab, rather than removing it. “That provides a dramatic savings in energy in air conditioning,” says Zboralski. The lack of ductwork also gives such hoods more flexibility. “We have powered bases that move the hood up and down for the height of different users, and we can put it on casters so it can even be moved from one lab to another.”

This FumeGard NU-156 Vertical Laminar Airflow Fume Hood consists of polypropylene to prevent damage from corrosive chemicals. (Source: NuAire)

At Thermo Fisher Scientific, these hoods use treated charcoal as the filter. “This molecular modification allows a wide base of chemicals to be utilized in that enclosure,” says Zboralski. In ordering a filter-based hood, the customer describes how the hood will be used and how often. “Then we can determine how long the filters will last,” Zboralski says. “We target applications where the filters will last at least two years.”

Zboralski also points out that Thermo Fisher Scientific makes this technology intelligent. “Every user gets a card that powers up the hood,” he explains. “This lets a safety person keep track of how the hood is being used and when the filter needs to be changed.”

Getting Rid of Rust
To give a fume hood longer life and eliminate the possibility of rusting, NuAire uses polypropylene. “We work in a niche industry, where people use a real, real corrosive chemical,” says Terry Thompson, polypro sales manager at NuAire. “All hoods are supposedly made to handle corrosive chemicals, but steel hoods eventually rust and that contaminates the user’s end product.” He adds, “Polypropylene stands up to virtually any chemical out there.”

Rust can also indicate a deficit in hood performance. “Once you see rust on the outside of the hood,” says Thompson, “it means that fumes are getting out.”

Buying that extra capability might cost 20 percent more when compared with a steel hood, but Thompson points out a range of economical benefits. “It’s not just that you don’t ever have to buy a new hood,” he says, “but you also save the time it takes to pull down an old hood and the lost research time when replacing it.”

For tomorrow’s labs or old labs getting a facelift, hoods like these enhance the efficiency and safety of research.

Join the Discussion
Rate Article: Average 0 out of 5
register or log in to comment on this article!

0 Comments

Add Comment

Text Only 2000 character limit

Page 1 of 1

Research Exchange

How to Build an Integrated Microscopy System for Live Cell Mechanotransduction Studies

How to Build an Integrated Microscopy System for Live Cell Mechanotransduction Studies

Aug 2

A new integrated microscopy system allows scientists to simultaneously stimulate and image live cell response in real-time.

Tips for Reducing Static Electricity

Tips for Reducing Static Electricity

Aug 1

Static electricity can affect automated instrumentation within the lab.

Microscopes for the Non-Microscopist: Multidisciplinary Research Using Optical Imaging

Microscopes for the Non-Microscopist: Multidisciplinary Research Using Optical Imaging

Jul 5

High quality microscopy is increasingly used by scientists in new areas of research.

Bringing the Cell Image into Focus

Nov 2 2010

Improvements in transmission electron microscope (TEM) technology increase the power of this imaging tool for the study of cell biology.

Evaluation of a New Nano-Type UV-Vis Spectrophotometer

Mar 3

Analysis of one- to four-microliter size samples for nucleic acids has become routine in many life science laboratories. However, until now, available instruments require considerable manipulation of the instrument and sample; some require manually recording the data. The user must typically lower and raise the arm manually, then wipe the sample manually from the target after each analysis. And fiberoptics used in some of these instruments are subject to deterioration.

Production of Recombinant Proteins and Monoclonal Antibodies in Hollow Fiber Bioreactors

Jan 25

While well-understood, robust and convenient, classical batch-style 2-D culture on non-porous supports or 3-D suspension culture in other devices are really not very biologically relevant models. Cell culture conditions can affect the quality of the antibody or protein produced.

Selecting Robots for Use in Drug Discovery and Testing

Dec 6 2010

Drug discovery and testing, with their need for speed, repeatability and verification, are ideally suited to benefit from robot automation. It is therefore not surprising that robots have been at the forefront of automation developments in both these areas.

HP Scalable Network Storage Systems for Life Sciences

Sep 13 2010

Life sciences research today is advancing exponentially, each step bringing us closer to the realization of truly personalized medicine–preventive care and treatments designed specifically for each individual. In the near future, PCPGM healthcare researchers expect to be able to use predictive genetic testing to create custom treatment plans for individuals and deliver dramatic improvements over today’s one-size-fits-all approach. But research capabilities are only part of the equation; current storage and operating capacities must also evolve to accommodate ever-expanding amounts of data before the goal of personalized medicine can be realized.

Using the Tecan Genesis Workstation to Automate a Cytometric Bead Array (CBA) Immunoassay

Mar 11 2010

The poster describe the process involved in automating a Cytometric Bead Array (CBA) immunoassay developed to measure relative concentrations of serum antibodies against Tetanus (TT), Sperm Whale Myoglobin (SWM) and Keyhole Limpet Hemocyanin (KLH) in KLH-immunized volunteers.

Ensuring Quality in Assays Performed with Automated Liquid Handlers

Feb 2 2010

The focus of this presentation is to highlight the need of ensuring quality in important assays performed with automated liquid handlers. Nearly all assays performed within a laboratory are volume-dependent. In turn, all concentrations of biological and chemical components in these assays, as well as the associated dilution protocols, are volume-dependent. Because analyte concentration is volume-dependent, an assay’s results might be falsely interpreted if liquid handler variability and inaccuracies are unknown or if the system(s) go unchecked for a long period.

Inkjet System for Protein Crystallography

Feb 1 2010

X-ray crystallography is used routinely by scientists to obtain the three dimensional structure of a biological molecule of interest.Such information can be used to determine how a pharmaceutical interacts with a protein target and what changes might improve functionality. However, the crystallization of macromolecules still remains a serious hindrance in structural determination despite impressive advances in screening methods and technologies.

Attention Deficit & Hyperactivity in a Drosophila Memory Mutant

Attention Deficit & Hyperactivity in a Drosophila Memory Mutant

Nov 9 2009

Action selection is modulated by external stimuli either directly or via memory retrieval. In a constantly changing environment, animals have evolved attention-like processes to effectively filter the incoming sensory stream. These attention-like processes, in turn, are modulated by memory. The neurobiological nature of how attention, action selection and memory are inter-connected is unknown. We describe here new phenotypes of the memory mutant radish in the fruit fly Drosophila.

Do eating attitudes predict early change in eating behaviors among women with bulimic disorders who are treated with cognitive behavioral therapy?

58 minutes ago

This study examined the eating attitudes that are associated with a reduction in bulimic behaviors during the key early stage of cognitive behavioral therapy (CBT). A case series of 41 patients with bulimia nervosa (full or partial syndrome) took...

Rheumatoid arthritis and anaesthesia.

1 hour ago

There has been a great deal of progress in our understanding and management of rheumatoid arthritis in recent years. The peri-operative management of rheumatoid arthritis patients can be challenging and anaesthetists need to be familiar with recent developments...

Primer and interviews: Advances in targeted gene modification.

1 hour ago

Gene targeting in mice, first reported 25 years ago, has led to monumental advances in the understanding of basic biology and human disease. The ability to employ a similarly straightforward method for gene manipulation in other experimental organisms would make...

Prokariotic Cell Collection in Denmark

Nov 6 2009

I would like to know about a prokariotic cell collection in Denmark. Is there a cell bank in this country? I need a Lactobacillus strain for a fermentation assay and this information about the bank is very helpful for me.

Request for Entries

Oct 16 2009

Ask the Experts is your chance to get the answers to questions on applications, materials, methods, processes, and technologies. Email you question to bst_web@advantagemedia.com, and the editors of Bioscience Technology will find an appropriate expert to answer it. Watch this space in the future to see the questions your colleagues are posting.

STAY INFORMED: SUBSCRIBE TO

Magazine and E-mail Newsletters

Loading...
E-mail:   
Loading...

Free Life Science Industry
Subscriptions

Magazine

wireless week

Newsletters

newsletters

Sign up now



MULTIMEDIA

Video:

Viewing SureFocus Slides

Jun 11 2010

A demonstration of SureFocus Microscope Slides in the review of AFB Smears. SureFocus Slides are a patent-pending breakthrough in tuberculosis detection, as their fluorescent staining circle remains visible during review, Fluorescence Microscopy.

Podcasts:

Allen Institute for Brain Research

Allen Institute for Brain Research

Oct 14 2009

Discussed in this interview are both the mouse brain project and the human cortex project with an emphasis on the importance of these projects to neuroscience research.

Top Stories and Headlines
EVERY DAY!

FREE Email Newsletter

Information: