Information Regarding Insulin Storage and Switching Between Products in an Emergency

Featured In: Regulatory News

By Federal Drug Administration Thursday, September 2, 2024

newsvine diigo google
slashdot
Share
Loading...

Information Regarding Insulin Storage and Switching Between Products in an Emergency

Back to Natural Disaster Response

Insulin Storage and Potency

Insulin from various manufacturers is often made available to patients in an emergency and may be different from a patient's usual insulin. After a disaster, patients in the affected area may not have access to refrigeration.  According to the product labels from all three U.S. insulin manufacturers, it is recommended that insulin be stored in a refrigerator at approximately 35 to 46 degrees F.  Unopened and stored in this manner, these products maintain potency until the expiration date on the package.  However, all of the available insulin products may be left unrefrigerated (between 59 and 86 degrees F) for up to 28 days and still maintain potency.

As a general rule, insulin loses its potency according to the temperature it is exposed to and length of that exposure. Under emergency conditions, you might still need to use insulin that has been stored above 86 degrees F.  Such extreme temperatures may cause insulin to lose potency, which could result in loss of blood glucose control over time.

In any case, you should try to keep insulin as cool as possible. Try to keep insulin away from direct heat and out of direct sunlight, but if you are using ice, also avoid freezing the insulin.

When properly stored insulin again becomes available, the insulin vials that have been exposed to these extreme conditions should be discarded and replaced. If patients or healthcare providers have specific questions about the suitability of their insulin, they may call the respective manufacturer at the following numbers:

Lilly: 1-800-545-5979
Sanofi-Aventis: 1-800-633-1610
Novo Nordisk: 1-800-727-6500

Insulin Switching

Switching insulin should always be done in consultation with a physician. If this is not possible under emergency conditions, the following recommendations may be considered:

Short-acting and rapid-acting insulins

One brand of regular insulin (e.g. Humulin R, Novolin R) may be substituted for another brand of regular insulin and for rapid-acting insulins (e.g., Humalog, NovoLog), and vice versa, on a unit-per-unit basis.

Intermediate and long-acting insulins

One intermediate-acting insulin product (e.g., Humulin N, Novolin N, Lente insulin)  may be substituted for another intermediate-acting insulin product on a unit-per-unit basis.  Likewise, these insulins may also be substituted for long-acting insulins (such as Lantus and Ultralente) on a unit-per-unit basis, or vice versa.  IMPORTANTLY, half of the NPH (or Lente) insulin dose should be given in the morning and half given in the evening.

Insulin mixes

Patients using pre-mixed insulin products (e.g., Humulin 70/30, Humalog Mix75/25, Novolin 70/30, NovoLog Mix 70/30) have two options to consider:

  • One insulin mix product may be substituted for another on a unit-per-unit basis.
  • If no other insulin mix is available, patients should first substitute an intermediate- or long-acting insulin on a unit-per-unit basis relative to the intermediate-acting component of the mix (e.g., in the examples above, approximately ¾ of the total unit dose of the mix), always making sure that the total dose of NPH (or Lente) insulin is split between morning and evening doses.
  • If regular or rapid-acting insulins are also available, they may be used before major meals along with the intermediate- or long-acting insulin (dosed as above) in doses equivalent to approximately ¼ of the total dose of pre-mixed insulin usually taken before that meal.

Insulin pumps

  • Patients using insulin pumps who must switch to injected insulin may substitute an intermediate or long-acting insulin for the 24-hour total basal dose of infused insulin on a unit-per-unit basis, always making sure that the total dose of NPH (or Lente) insulin is split between morning and evening doses.
  • If regular or rapid acting insulin is also available, patients should administer mealtime insulin according to their previous system for calculating their bolus insulin doses.

Back to Natural Disaster Response

    

SOURCE

Join the Discussion
Rate Article: Average 0 out of 5
register or log in to comment on this article!

0 Comments

Add Comment

Text Only 2000 character limit

Page 1 of 1

Research Exchange

Bringing the Cell Image into Focus

Nov 2

Improvements in transmission electron microscope (TEM) technology increase the power of this imaging tool for the study of cell biology.

Finding a Cure for Spinal Cord Injury with On-Demand LIMS

Oct 25

The Miami Project to Cure Paralysis finds an on-demand laboratory information management system (LIMS) helps to accelerate discovery in its HCS projects.

Saving Cells: Image Processing for Improved Viability, Part II: Iterative Deconvolution

Oct 25

3D light microscopy and deconvolution provide a means to investigate 3D structure, providing near-confocal quality images without the temporal requirements or potentially damaging phototoxicity associated with other 3D imaging technologies. This article is Part II in a series regarding viability, resolution improvement, and measurement in fluorescence imaging. Part I focused on spectral unmixing.

Saving Cells: Image Processing for Improved Viability

Sep 22

This article is Part I of a two-part series regarding viability, resolution improvement, and measurement in fluorescence imaging. Part II will focus on deconvolution.

Selecting Robots for Use in Drug Discovery and Testing

Dec 6

Drug discovery and testing, with their need for speed, repeatability and verification, are ideally suited to benefit from robot automation. It is therefore not surprising that robots have been at the forefront of automation developments in both these areas.

HP Scalable Network Storage Systems for Life Sciences

Sep 13

Life sciences research today is advancing exponentially, each step bringing us closer to the realization of truly personalized medicine–preventive care and treatments designed specifically for each individual. In the near future, PCPGM healthcare researchers expect to be able to use predictive genetic testing to create custom treatment plans for individuals and deliver dramatic improvements over today’s one-size-fits-all approach. But research capabilities are only part of the equation; current storage and operating capacities must also evolve to accommodate ever-expanding amounts of data before the goal of personalized medicine can be realized.

Step up to the MIQE

Mar 30

Over the years, polymerase chain reaction (PCR) has evolved into a readily automated, high throughput quantitative technology. Real-time quantitative PCR (qPCR) has become the industry standard for the detection and quantification of nucleic acids for multiple application, including quantification of RNA levels. But a lack of consensus among researchers on how to best perform and interpret qPCR experiments presents a major hurdle for advancement of the technology. This problem is exacerbated by insufficient experimental detail in published work, which impedes the ability of others to accurately evaluate or replicate reported results.

Fast Optimization of a Multiplex Influenza Identification Panel Using a Thermal Gradient

Mar 30

The year 2009 was marked by the emergence of a novel influenza A (H1N1) virus that infects humans. There is a need to identify the different strains of influenza virus for purposes of monitoring the H1N1 strain pandemic and for other epidemiological and scientific purposes.

Using the Tecan Genesis Workstation to Automate a Cytometric Bead Array (CBA) Immunoassay

Mar 11

The poster describe the process involved in automating a Cytometric Bead Array (CBA) immunoassay developed to measure relative concentrations of serum antibodies against Tetanus (TT), Sperm Whale Myoglobin (SWM) and Keyhole Limpet Hemocyanin (KLH) in KLH-immunized volunteers.

Ensuring Quality in Assays Performed with Automated Liquid Handlers

Feb 2

The focus of this presentation is to highlight the need of ensuring quality in important assays performed with automated liquid handlers. Nearly all assays performed within a laboratory are volume-dependent. In turn, all concentrations of biological and chemical components in these assays, as well as the associated dilution protocols, are volume-dependent. Because analyte concentration is volume-dependent, an assay’s results might be falsely interpreted if liquid handler variability and inaccuracies are unknown or if the system(s) go unchecked for a long period.

Inkjet System for Protein Crystallography

Feb 1

X-ray crystallography is used routinely by scientists to obtain the three dimensional structure of a biological molecule of interest.Such information can be used to determine how a pharmaceutical interacts with a protein target and what changes might improve functionality. However, the crystallization of macromolecules still remains a serious hindrance in structural determination despite impressive advances in screening methods and technologies.

Attention Deficit & Hyperactivity in a Drosophila Memory Mutant

Attention Deficit & Hyperactivity in a Drosophila Memory Mutant

Nov 9 2009

Action selection is modulated by external stimuli either directly or via memory retrieval. In a constantly changing environment, animals have evolved attention-like processes to effectively filter the incoming sensory stream. These attention-like processes, in turn, are modulated by memory. The neurobiological nature of how attention, action selection and memory are inter-connected is unknown. We describe here new phenotypes of the memory mutant radish in the fruit fly Drosophila.

Growth suppression of human hepatocellular carcinoma xenografts by a monoclonal antibody CH12 directed to epidermal growth factor receptor variant III.

Dec 19

Human hepatocellular carcinoma (HCC) is considered difficult to cure because its resistant to radio- and chemotherapy and high recurrence rate after curative liver resection. Epidermal growth factor receptor variant III (EGFRvIII) has shown to express in HCC...

Nutrients and the Pkh1/2 and Pkc1 protein kinases control mRNA decay and P-body assembly in yeast.

Dec 19

Regulated mRNA decay is essential for eukaryotic survival but the mechanisms for regulating global decay and coordinating it with growth, nutrient and environmental cues are not known. Here we show that a signal transduction pathway containing the Pkh1/Pkh2...

Kallikrein-5 promotes cleavage of desmoglein-1 and loss of cell-cell cohesion in oral squamous cell carcinoma.

Dec 19

Oral squamous cell carcinoma (OSCC) ranks among the top 8 causes of cancer death worldwide, with only a 60% 5-year survival rate, highlighting the need for discovery of novel biomarkers and therapeutic targets. We have previously reported that expression of a...

Nuclear choline acetyltransferase activates transcription of a high-affinity choline transporter.

Dec 19

Choline acetyltransferase (ChAT) synthesizes the neurotransmitter, acetylcholine (ACh), at cholinergic nerve terminals. ChAT contains nuclear localization signals (NLSs) and is also localized in the nuclei of neural and non-neuronal cells. Nuclear ChAT might...

Prokariotic Cell Collection in Denmark

Nov 6 2009

I would like to know about a prokariotic cell collection in Denmark. Is there a cell bank in this country? I need a Lactobacillus strain for a fermentation assay and this information about the bank is very helpful for me.

Request for Entries

Oct 16 2009

Ask the Experts is your chance to get the answers to questions on applications, materials, methods, processes, and technologies. Email you question to bst_web@advantagemedia.com, and the editors of Bioscience Technology will find an appropriate expert to answer it. Watch this space in the future to see the questions your colleagues are posting.

STAY INFORMED: SUBSCRIBE TO

Magazine and E-mail Newsletters

Loading...
E-mail:   

MULTIMEDIA

Video:

Viewing SureFocus Slides

Jun 11

A demonstration of SureFocus Microscope Slides in the review of AFB Smears. SureFocus Slides are a patent-pending breakthrough in tuberculosis detection, as their fluorescent staining circle remains visible during review, Fluorescence Microscopy.

Podcasts:

Allen Institute for Brain Research

Allen Institute for Brain Research

Oct 14 2009

Discussed in this interview are both the mouse brain project and the human cortex project with an emphasis on the importance of these projects to neuroscience research.

Information: